Certified Cardiac Medical Device Distributor

CALL 888-891-1200 Email an Order

REQUEST PRODUCT INFO

  • medalliancesolutions
  • An Experienced Cardiac Medical
    Device Distributor

  • Reduce the Potential for Tissue Damage with The Surge PEAK Left Heart Vent Cannula

    1. Home
    2. /
    3. General
    4. /
    5. Reduce the Potential for...

    Reduce the Potential for Tissue Damage with The Surge PEAK Left Heart Vent Cannula

    Cardiothoracic surgeons know the complications that can arise while venting the left heart during cardiopulmonary bypass. One of the common risks while inserting the cannula is tissue damage. Tissue damage and/or perforation can result in further complications during the healing process or even surgical intervention for repair.

    Though traditional left ventricular vent cannulas have been used for decades, their designs do not mitigate potential trauma to the patient during insertion. Surgeons can reduce the risk of damage and perforations in the pulmonary vein, left atrium or the left ventricle by using a high-quality cannula that has specifically designed features for smooth insertion.

    Surge Cardiovascular’s PEAK Left Heart Vent Cannula mitigates damage and perforation through an innovative design. While traditional introducer or cannula tips are stepped or pointed and can result in damage or perforation, the PEAK LV Vent has a fully rounded introducer tip extending just beyond the cannula. The rounded nature of the tip allows for smooth passage through the anatomy.

    In addition to the rounded tip, the frosted polymer coating on the introducer allows the cannula to be shaped via the malleable core but prevent it from sticking or grabbing upon removal through the bent configuration. The malleable stylet enables surgeons to confidently place and maintain cannula position in the apex of the left ventricle while the introducer retains its shape. The polymer stylet makes removal smooth.

    This atraumatic insertion and removal of the stylet give surgeons confidence in the protection of the cardiac anatomy from perforation and surface damage. The product is available in three sizes to match each patient’s specific needs.

    The enhanced design of the PEAK Left Heart Vent Cannula offers surgeons the ability to improve patient safety. To learn more about the PEAK Left Heart Vent Cannula and other Surge Cardiovascular products, contact us by email or call (888) 891-1200.


    MED Alliance Solutions is a medical device distributor that has been dedicated to meeting the needs of our clinical customers and manufacturing partners since 2007. We specialize in the sales, marketing, importation, logistics and distribution of innovative, high-quality and cost-effective cardiovascular and cardiothoracic medical devices on a national basis.

    Please follow us on LinkedIn, Facebook and Twitter for product updates!

    Related Posts
    Delacroix-Chevalier: Thoracic Surgery Portfolio
    Delacroix-Chevalier: Thoracic Surgery Portfolio

    Delacroix-Chevalier offers quality retractors and instrumentation to facilitate multiple thoracic surgery approaches.

    Study Concludes the Coaxial Thoracic Drain Contributes to Improving Postoperative Recovery
    Study Concludes the Coaxial Thoracic Drain Contributes to Improving Postoperative Recovery

    Dr. Tadaaki Koyama, Director of Cardiovascular Surgery at Kobe City Medical Centre General Hospital in Japan, presented his findings of Read more

    Reap the Benefits of the Unique Redax Coaxial Catheter in Thoracic Surgery Procedures
    Reap the Benefits of the Unique Redax Coaxial Catheter in Thoracic Surgery Procedures

    Thoracic surgery procedures such as pulmonary lobectomies/segmentectomies require fluid and air removal from the pleural cavity to prevent postoperative complications. Read more

    Redax Fluted Smart Drain – Progressive Solutions in Wound Drainage
    Redax Fluted Smart Drain – Progressive Solutions in Wound Drainage

    36% of chest tubes clog or become completely occluded following surgery.[1] Occluded drains following any surgery can result in costly Read more

  • Contact Information

    MED Alliance Solutions
    2175 Oakland Drive
    Sycamore, IL 60178

    TOLL FREE: 888-891-1200
    PHONE: 630-443-7070

  • Copyright © 2023 Med Alliance Solutions, LLC REP LOGIN PROUD MEMBER OF IMDA